Article ID Journal Published Year Pages File Type
4921417 Fusion Engineering and Design 2016 5 Pages PDF
Abstract
In fusion devices, plasma is contained in a vacuum vessel. The vacuum vessel cannot withstand a pressure above atmospheric. Any damage of in-vessel components could lead to water ingress and may lead to pressure increase and possible damage of vacuum vessel. In order to avoid such undesirable consequences, the pressure increase protection system is designed. In this article, the processes occurring in the vacuum vessel and pressure increase protection system of W7-X device during LOCA (small and guillotine pipe break) event are analyzed. The model of W7-X cooling system, vacuum vessel and pressure increase protection system was developed using RELAP5 code. Numerical analysis of partial and guillotine break of 40 mm diameter pipe of cooling system was performed. Calculation results showed that burst disc of the pressure increase protection system does not open when the cross section area of partial break in the cooling system is smaller than 1 mm2. During the guillotine break of cooling system, the burst disc opens, but pressure increase protection system is capable to prevent overpressure of the vacuum vessel.
Keywords
Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , ,