Article ID Journal Published Year Pages File Type
4925408 Nuclear Engineering and Design 2017 8 Pages PDF
Abstract
The steady state and transient state analysis for LOCA is carried out using the best estimate system code RELAP5. For the conventional UO2 fuel, fission product releases simultaneously when the cladding fails. But for the FCM fuel, the radioactive material can be contained in the fuel pellet even after the cladding failure since enveloping the TRISO particles within a dense SiC matrix provides multiple barriers to fission product release. Consequently, although the Zircalloy cladding fails, there is still 3500 s available for operator actions before the start of FCM fuel melting occurs even through the SB-LOCA occurring without ECCS, and there is still 1443 s available even through the LB-LOCA occurring without ECCS. The results of the accident analysis without ECCS would be useful in understanding cladding and fuel failure progression and could provide guidelines in establishing detailed accident management procedures to design the proper ECCS in the future.
Keywords
Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , , , ,