Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
4926269 | Renewable Energy | 2017 | 13 Pages |
Abstract
The presented measurement results reveal that evaporation performance in thin film operation is crucially governed by fluid side heat transfer (UA raise by 146% within tested Reynolds numbers) and wetting conditions while fin sheet thickness plays a marginal role (8% increase of UA). In partially flooded operation performance strongly depends on filling level. Apart from some refinement potential of the thin film model, the simulations reflect evaporation dynamics and effects of influencing factors fairly well which indicates that the employed model approach could be a suitable tool for an effective optimization of evaporator geometry and process parameters.
Keywords
Related Topics
Physical Sciences and Engineering
Energy
Renewable Energy, Sustainability and the Environment
Authors
Rahel Volmer, Julia Eckert, Gerrit Füldner, Lena Schnabel,