Article ID Journal Published Year Pages File Type
4980185 Journal of Loss Prevention in the Process Industries 2017 10 Pages PDF
Abstract
The test data were compared with the predictions of the vent area correlations provided in NFPA 68. For all but the fourth test series (i.e., congestion array occupying ¼ of the rig), the average internal peak pressures were approximately a factor of 2 larger than those predicted by NFPA 68. Adjustments to the NFPA 68 correlation were investigated to improve the agreement with the current test data.
Related Topics
Physical Sciences and Engineering Chemical Engineering Chemical Health and Safety
Authors
, , ,