Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
4988544 | Journal of Membrane Science | 2017 | 25 Pages |
Abstract
Peptide fouling occurring on anion- (AEMs) and cation-exchange membranes (CEMs) is one of the most serious issues of conventional electrodialysis (ED) process for hydrolysate demineralization. Nonetheless, recent studies discussed the advantages of non-conventional ED phenomena such as water splitting and electroconvection on decreasing scaling and fouling. Thereby, peptide fouling was characterized using four different ED regimes: no current applied, underlimiting (conventional), limiting (water splitting) and overlimiting (electroconvection and water splitting) conditions. Results demonstrated that fouling-related interactions were mainly electrostatic with AEMs whereas they were both electrostatic and hydrophobic with CEMs. After 60Â min, the demineralization rate was six times higher in overlimiting than underlimiting conditions. In addition, peptide fouling was 62% and 36% lower in overlimiting condition for AEMs and CEMs, respectively. It was hypothesized that (1) water splitting would have repealed the peptide charges through its "barrier effect" and (2) electroconvective vortices generated at the membranes interfaces would have washed-out their surfaces and hampered the attachment of peptides. Interestingly, ED under overlimiting conditions is a promising way to avoid peptide fouling. Consequently, membranes lifetime would be longer and new ED applications would be possible.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Filtration and Separation
Authors
Mathieu Persico, Sergey Mikhaylin, Alain Doyen, Loubna Firdaous, Victor Nikonenko, Natalia Pismenskaya, Laurent Bazinet,