Abstract
The experiments were performed to analyze the influence of apex angle on thermal and hydraulic characteristics of triangular duct for Reynolds number range from 2000 to 16,000. Four different triangular ducts of apex angle 30°, 60°, 90° and 110° were fabricated for the experimentation. The one side of the duct is roughened with dimple shaped roughness element. The both relative shortway length (s/e) and relative longway length (l/e) of dimple shaped roughened element was kept constant (i.e., 10) but relative roughness height (e/D) is varied from 0.016 to 0.038. Result shows that apex angle plays an important role in heat transfer. The experimental results are presented in a form of correlation for Nusselt number (Nu) and friction factor (f).
Keywords
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Fluid Flow and Transfer Processes
Authors
Varun Goel, Pankaj Guleria, Rajneesh Kumar,