Abstract
Efficient cooling system is an essential part of heavy duty extrusion pelleting line which plays an important role in production engineering of megaton polyolefin. In this paper, a new cooling system based on two-phase closed thermosyphon (TPCT) used in heavy duty extrusion pelleting line was presented. Comparative experimental results show that thermal performance of TPCT is more efficient, and the temperature uniformity is much better than traditional extruder (similar to coiled heat exchanger) in preheating process and extrusion reaction process. The effects of different operation conditions: filling ratio (0.2, 0.35, 0.5, 0.65 and 0.8), flow rate of cooling water (120Â L/h, 180Â L/h, 240Â L/h, 300Â L/h and 360Â L/h) and heating power (7Â kW, 9Â kW and 11Â kW) on thermal characteristics were experimental investigated, respectively. The results show that temperature of barrel inner wall increased significantly as filling ratio increased and evaporator appeared dry out when filling ratio is 0.2. The flow rate of cooling water affected the condenser section obviously, but had little influence on evaporation section. With increase of heating power, the start-up time decreases and the heat transfer coefficient increased. An ideal cooling scheme was concluded: the liquid filling ratio was 0.35, the cooling water flow rate was 180Â L/h and the heating power was 11Â kW when working medium was water.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Fluid Flow and Transfer Processes
Authors
Liangzhi Xia, Dandan Dong, Hongchun Zhang, Zewu Wang, Caiyuan Yu,