Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
5011027 | Applied Acoustics | 2017 | 5 Pages |
Abstract
In order to control low frequency noise in exhaust pipe, this paper puts forward a new concept of H-Q tube based semi-active muffler device. The semi-active muffler device and bench testing system have been designed and operated. Finite element simulation study on semi-active muffler and experimental study on semi-active muffler and passive muffler have been carried on. The effect of simulation and experiment are consistent. The semi-active muffler device acts well in low frequency band, especially between 50Â Hz and 150Â Hz. The average level of noise reduction is around 35Â dB, which is much better than passive muffler. Between 150Â Hz and 350Â Hz, semi-active muffler has a better performance than passive muffler; above 350Â Hz, it has worse performance compared with the passive muffler.
Keywords
Related Topics
Physical Sciences and Engineering
Engineering
Mechanical Engineering
Authors
Ya-wei Zhu, Fa-wang Zhu, Yan-shan Zhang, Qing-guo Wei,