Article ID Journal Published Year Pages File Type
5011027 Applied Acoustics 2017 5 Pages PDF
Abstract
In order to control low frequency noise in exhaust pipe, this paper puts forward a new concept of H-Q tube based semi-active muffler device. The semi-active muffler device and bench testing system have been designed and operated. Finite element simulation study on semi-active muffler and experimental study on semi-active muffler and passive muffler have been carried on. The effect of simulation and experiment are consistent. The semi-active muffler device acts well in low frequency band, especially between 50 Hz and 150 Hz. The average level of noise reduction is around 35 dB, which is much better than passive muffler. Between 150 Hz and 350 Hz, semi-active muffler has a better performance than passive muffler; above 350 Hz, it has worse performance compared with the passive muffler.
Related Topics
Physical Sciences and Engineering Engineering Mechanical Engineering
Authors
, , , ,