Article ID Journal Published Year Pages File Type
5011040 Applied Acoustics 2017 7 Pages PDF
Abstract
This paper reports the binaural active noise control (ANC) system developed to deal with factory noise. The control points are located in the vicinity of the left and right ears of a worker sitting along the production line. Due to the complicated safety requirements in the factory, secondary sources and error microphones are not allowed to be placed near the worker. Therefore, the proposed ANC system employs the feedforward structure and adopts the parametric array loudspeakers (PALs) as the secondary sources. The PAL is a type of directional loudspeaker that generates a much narrower sound field as compared to the conventional loudspeaker. Once the proposed ANC system has been trained offline, the error microphones can be removed. The performance of the binaural ANC system is successfully demonstrated based on a digital signal processor (DSP) implementation.
Keywords
Related Topics
Physical Sciences and Engineering Engineering Mechanical Engineering
Authors
, , ,