Abstract
The analysis shows that the estimated and manually measured values of the fuel moisture content do not differ by more than 3%. This deviation indicates that the indirect fuel moisture calculation method is sufficiently precise and the calculated moisture content varies proportionally to changes in the thermal capacity of the economiser. By smoothing the data using sliding weighted averaging, the oscillations of the fuel moisture content were identified.
Related Topics
Physical Sciences and Engineering
Energy
Energy (General)
Authors
N. StriÅ«gas, L. VorotinskienÄ, R. Paulauskas, R. Navakas, A. Džiugys, L. Narbutas,