Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
5013675 | Engineering Failure Analysis | 2017 | 14 Pages |
Abstract
The results of roughness tests of the drain surface indicate that roughness is another factor leading to corrosion. Drains should be manufactured from polished surface finish metal sheet. To avoid the risk of corrosion in the future, the unsuitable grade of steel should be replaced by a higher-alloyed stainless steel grade.
Related Topics
Physical Sciences and Engineering
Engineering
Industrial and Manufacturing Engineering
Authors
MirosÅaw Szala, Karolina Beer-Lech, Mariusz Walczak,