Abstract
This work presents the experimental evaluation of R-513A (GWPâ=â573) and R-450A (GWPâ=â547) as R-134a (GWPâ=â1301) drop-in replacements and as R-507A (GWPâ=â3987) retrofits in a commercial direct expansion refrigeration system for medium temperature applications (2â°C). The evaluation covered 24-hour tests using a single-stage cycle with semi-hermetic compressor, an electronic expansion valve customized for each refrigerant and a commercial vertical cabinet with doors placed inside a climatic chamber. The tests were performed at three water dissipation temperatures (23.3, 32.8 and 43.6â°C). Experimental results indicate that R-513A and R-450A can operate with R-134a plants, with increments in energy consumption between â1.6 to +1.2% for R-513A and from +1.3 to +6.8% for R-450A, whereas in comparison with R-507A, R-513A offered reductions in energy consumption between 4.4 to 8.2% and R-450A between 0 to 3.3%. The paper analyzes the modification of the operating pressures/temperatures and the energy indicators using the four refrigerants.
Keywords
Related Topics
Physical Sciences and Engineering
Engineering
Mechanical Engineering
Authors
Rodrigo Llopis, Daniel Sánchez, Ramón Cabello, Jesús Catalán-Gil, Laura Nebot-Andrés,