Article ID Journal Published Year Pages File Type
5021155 Composites Part B: Engineering 2017 25 Pages PDF
Abstract
The high vulnerability of existing Reinforced Concrete (RC) structures, even to moderate seismic events, has been confirmed from recent post-earthquake surveys. Short and wall-like RC columns are particularly prone to brittle failures, governed by concrete crushing. To reduce the vulnerability of existing RC columns, the use of externally bonded Fibre Reinforced Polymer (FRP) reinforcement has been recognized as an effective method for preventing the aforementioned brittle failure and, hence, increasing members' lateral capacity and ductility. In the first part of this study, the results of an observational analysis on columns shear failures in RC buildings severely damaged after the L'Aquila earthquake are presented. The second part of the study presents and discusses the results of an experimental program carried out on seven short RC columns governed by shear failure under load reversal and compressive axial load. Both columns in “as built” configuration and strengthened in shear with discontinuous carbon FRP (CFRP) strips have been tested. Two classes of concrete have been used, in order to simulate structures with medium or poor material quality, and different external reinforcement ratios have been investigated. The specimens' responses have been analysed in terms of failure modes, strength/deformation capacity and strain distribution in CFRP strips.
Related Topics
Physical Sciences and Engineering Engineering Engineering (General)
Authors
, , , , ,