Article ID Journal Published Year Pages File Type
5028246 Procedia Engineering 2017 7 Pages PDF
Abstract

In this paper we compare 6 algorithms for optimal pressure sensor placement by applying them to a real world system. The targets of these comparisons were a) to see how robust sensor positions are in terms of different mathematical approaches b) to derive the optimal sensor placement for the purpose of small leakage localisation in a case study distribution system. Therefore, we created artificial leakage scenarios in the real world system by opening fire hydrants at different flow rates. Pressure was measured at all hydrants that were found to be an ideal sensor position by any of the applied methods. Based on these measurements, model-based leakage localization was run using data from the different sensor sets. To compare leakage localization performance the distance between the found to the real world leak was calculated. The results of the sensor placement have shown similarities in sensor positions for graph theory based methods, but the ideal sensor positions derived from the sensitivity based methods varied strongly. The localisation results have shown that leaks down to 0.5 l/s can be located but for different leak positions different sensor sets, mainly those with sensors close to the leak position, led to the best performance.

Related Topics
Physical Sciences and Engineering Engineering Engineering (General)
Authors
, ,