Article ID Journal Published Year Pages File Type
5029058 Procedia Engineering 2017 7 Pages PDF
Abstract

Analysis of dielectric barrier discharge (DBD) plasma reactor electrically has been done. DBD as low-temperature plasma was used on liquid wastewater palm oil mill effluent (POME) treatment. The dielectric barrier discharge plasma reactor consists of electrodes in the stainless made of screw rod with a length of 40 cm and diameter of 1.84 cm and outer electrode as winding coil with a diameter of 2.25 cm. The outer electrode was made of copper wire windings with a diameter of 0.87 mm that was wrapped in a Pyrex tube with 0.25 cm thick, with a 20 mm inner diameter and tube length of 30 cm. Plasma reactor purged with argon gas discharge flow at 4 L/min which was connected to an AC voltage of 4 kV and frequency of 15 kHz. POME was inserted into the reactor by the time variation of 0, 30, and 60 minutes. The most optimal results in 60 minutes with a Chemical Oxygen Demand (COD) value of 115.62 mg/L or still 18% compare with an initial and TSS value of 1018 mg /L or rest 85%. We also determined the charges carrier mobility by using modified Robinson Equation, and we found that average mobility with samples is always high than average mobility without samples.

Related Topics
Physical Sciences and Engineering Engineering Engineering (General)
Authors
, , , , , , ,