Article ID Journal Published Year Pages File Type
5029723 Procedia Engineering 2016 4 Pages PDF
Abstract

This paper presents the setting up of a test stand, the design and construction of a furnace and the testing procedure in order to analyse the behaviour of steel beam to column end-plate bolted connections under the post-earthquake fire action. 12 real scale beam - node - column substructures were created for this goal. The main problem was how to simulate the seismic action on the specimens immediately followed by fire action. For the first part, the recommendations inside the document of ECCS - Technical Committee 1 were developed and applied for this case; for the fire action, the special furnace was designed and constructed around the connection.

Related Topics
Physical Sciences and Engineering Engineering Engineering (General)
Authors
,