Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
5031650 | Biosensors and Bioelectronics | 2017 | 27 Pages |
Abstract
Herein, we report a scalable synthesis of multifunctional conducting polyacrylic acid (PAA) hydrogel (MFH) integrated with reduced grapheme oxide (rGO), vinyl substituted polyaniline (VS-PANI) and lutetium Phthalocyanine (LuPc2) as three dimensional robust matrix for glucose oxidase (GOx) immobilization (PAA-rGO/VS-PANI/LuPc2/GOx-MFH). We have integrated the multicomponents such as PAA with rGO, and VS-PANI through free radical polymerization using methylene bis-acrylamide, and ammonium persulphate as the cross linker and initiator. The LuPc2 was then doped to form multifunctional hydrogel (PAA-rGO/VS-PANI/LuPc2-MFH). Finally, biosensor was fabricated by immobilizing GOx into PAA-rGO/VS-PANI/LuPc2-MFH and subsequently used for electrochemical detection of glucose. The PAA-rGO/VS-PANI/LuPc2/GOx-MFH biosensor exhibited high sensitivity (15.31 μA mMâ1 cmâ2) for the detection of glucose over a concentration range of 2-12 mM with a low detection limit of 25 µm. The PAA-rGO/VS-PANI/LuPc2-MFH biosensor showed a fast response time (1 s) to the addition of glucose with high storage stability of 3 months. The real sample analysis reveals that PAA-rGO/VS-PANI/LuPc2/GOx-MFH could be effectively used as an electrochemical biosensor in industrial as well clinical diagnosis.
Related Topics
Physical Sciences and Engineering
Chemistry
Analytical Chemistry
Authors
H. Al-Sagur, S. Komathi, M.A. Khan, A.G. Gurek, A. Hassan,