Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
5135096 | Journal of Chromatography A | 2017 | 8 Pages |
Abstract
Here, a methodology for the rapid screening of antibody extraction conditions using a microfluidic channel-based toolbox is presented. A first microfluidic structure allows a simple negative-pressure driven rapid screening of up to 8 extraction conditions simultaneously, using less than 20 μL of each phase-forming solution per experiment, while a second microfluidic structure allows the integration of multi-step extraction protocols based on the results obtained with the first device. In this paper, this microfluidic toolbox was used to demonstrate the potential of LYTAG fusion proteins used as affinity tags to optimize the partitioning of antibodies in ATPE processes, where a maximum partition coefficient (K) of 9.2 in a PEG 3350/phosphate system was obtained for the antibody extraction in the presence of the LYTAG-Z dual ligand. This represents an increase of approx. 3.7 fold when compared with the same conditions without the affinity molecule (K = 2.5). Overall, this miniaturized and versatile approach allowed the rapid optimization of molecule partition followed by a proof-of-concept demonstration of an integrated back extraction procedure, both of which are critical procedures towards obtaining high purity biopharmaceuticals using ATPE.
Related Topics
Physical Sciences and Engineering
Chemistry
Analytical Chemistry
Authors
Eduardo J.S. Bras, Ruben R.G. Soares, Ana M. Azevedo, Pedro Fernandes, Miguel Arévalo-RodrÃguez, Virginia Chu, João P. Conde, M. Raquel Aires-Barros,