Article ID Journal Published Year Pages File Type
5142394 Arabian Journal of Chemistry 2017 6 Pages PDF
Abstract
A simple, sensitive, precise and specific high performance liquid chromatography method was developed and validated for the determination of rizatriptan in rizatriptan benzoate tablet. The separation was carried out by using a mobile phase consisting of acetonitrile: pH 3.4 phosphate buffer in ratio of 20:80. The column used was Zorbax SB CN 250 mm × 4.6 mm, 5 μ with a flow rate of 1 ml/min using UV detection at 225 nm. The retention time of rizatriptan and benzoic acid was found to be 4.751 and 8.348 min respectively. A forced degradation study of rizatriptan benzoate in its tablet form was conducted under the condition of hydrolysis, oxidation, thermal and photolysis. Rizatriptan was found to be stable in basic buffer while in acidic buffer was found to be degraded (water bath at 60 °C for 15 min). The detector response of rizatriptan is directly proportional to concentration ranging from 30% to 160% of test concentration i.e. 15.032 to 80.172 mcg/ml. Results of analysis were validated statistically and by recovery studies (mean recovery = 99.44). The result of the study showed that the proposed method is simple, rapid, precise and accurate, which is useful for the routine determination of rizatriptan in pharmaceutical dosage forms.
Related Topics
Physical Sciences and Engineering Chemistry Chemistry (General)
Authors
, , , , ,