Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
5202450 | Polymer Degradation and Stability | 2013 | 10 Pages |
Abstract
Porous poly(ε-caprolactone) (PCL) scaffolds are widely used as in vivo implants in tissue engineering, and their long-term degradation behaviors are of great importance for their in vivo performances. However, the influence of porosity on long-term degradation of PCL scaffold in phosphate buffer solution (PBS) has been rarely reported so far. Herein, a 72-week degradation study of PCL scaffolds with various porosities was conducted to elucidate the changes of physico-chemical properties such as weight, molecular weight, morphology and compressive modulus. Within 72 weeks, PCL scaffolds experienced three stages: stable stage, mechanical loss stage and structural collapse stage. The higher porosity induced the severer loss of weight, molecular weight and compressive modulus. It was found that a minimal acid autocatalysis also happened in the scaffold samples with low porosities (less than 85%). Cellular response on the scaffolds with various porosities was further evaluated. The cell ingrowth improved on the scaffold with high porosity (e.g. S-10) in contrast to those with low porosity (e.g. S-6 and S-4). The combined results demonstrated that an optimal porosity of PCL scaffolds should be designed greater than 90% due to the appropriate degradation rate and good cell performance.
Related Topics
Physical Sciences and Engineering
Chemistry
Organic Chemistry
Authors
Qingchun Zhang, Yun Jiang, Yan Zhang, Zhaoyang Ye, Wensong Tan, Meidong Lang,