Article ID Journal Published Year Pages File Type
5206359 Polymer Testing 2013 7 Pages PDF
Abstract
Internal pressurization testing at room temperature was performed to evaluate the effect of flame-spraying aluminum-12silicon on the leakage behavior of fibre-reinforced composite tubes fabricated by filament winding, and covered with garnet sand. A group of specimens were completely coated with flame-sprayed metal particles and another set remained uncoated. t-tests were conducted at a significance level of α = 0.05 to analyze the effect of the coating on the leakage behavior of the specimens. Ultraviolet imaging was used to illustrate a characteristic leakage pattern of the composite tubes. Coated specimens exhibited slightly higher mean leakage and burst pressures than the uncoated specimens. The t-test results provided strong statistical evidence that the flame spraying process employed did not damage the filament wound tubes covered with garnet sand.
Related Topics
Physical Sciences and Engineering Chemistry Organic Chemistry
Authors
, , ,