Article ID Journal Published Year Pages File Type
5206620 Polymer Testing 2013 6 Pages PDF
Abstract
The main goal of this work is to identify two polyamides (PA11 and PA1012) by mass spectrometry including pyrolysis-GC/MS and MALDI-TOF MS. PA11 and PA1012 have similar properties and cannot be distinguished by many other methods. Using pyrolysis-GC/MS, the pyrograms of PA11 and PA1012 at 600 °C were compared. Specific pyrolyzates for PA11 and PA1012 were obtained, 2-azacyclotridecanone for PA11 and 1,10-diaminodecane, 1,10-dicyanodecane for PA1012, respectively, which was the basis to distinguish them. Meanwhile, MALDI-TOF MS can give specific repeat unit for these two polyamides, dehydrated 11-aminoundecanoic acid (M = 183) for PA11, acetylate of dodecanedioic acid and diaminodecane (M = 366) for PA1012, which can be another means of identifying them.
Related Topics
Physical Sciences and Engineering Chemistry Organic Chemistry
Authors
, , , , , ,