Article ID Journal Published Year Pages File Type
53346 Catalysis Today 2016 6 Pages PDF
Abstract

•Catalytic membrane reactor based on Pd-loaded polypropylene porous hollow fibers.•Single-stage removal of TCE from water by hydrodechlorination in CMR.•Degree of water purification is not less than 98%.•Hydrogen chloride does not impair Pd catalyst activity.

This work describes a single-stage method for the removal of chlorine-containing species from water using a catalytic membrane reactor based on Pd-loaded porous polypropylene hollow fiber membranes. The kinetics of this process is characterized. The degree of water purification is shown to be not less than 98%.

Graphical abstractFigure optionsDownload full-size imageDownload high-quality image (157 K)Download as PowerPoint slide

Related Topics
Physical Sciences and Engineering Chemical Engineering Catalysis
Authors
, , , , ,