Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
5356017 | Applied Surface Science | 2011 | 8 Pages |
Abstract
⺠Formation of HA/TiO2 coating on Ti-6Al-4V alloy may improve the corrosion behavior. ⺠Effect of voltage and time on PEO process for HA formation was investigated. ⺠For formation of HA phase with titania a voltage of 500 V is needed. ⺠At 500 V, the amount of HA phase increased with increasing the treatment time. ⺠The best corrosion behavior was observed for the sample coated at 500 V and 15 min.
Related Topics
Physical Sciences and Engineering
Chemistry
Physical and Theoretical Chemistry
Authors
M. Montazeri, C. Dehghanian, M. Shokouhfar, A. Baradaran,