Article ID Journal Published Year Pages File Type
5436878 Cement and Concrete Composites 2017 24 Pages PDF
Abstract
Fiber reinforced polymer (FRP) is a prevalent material for strengthening or retrofitting concrete structures. It has been found that the effectiveness of entire strengthening or retrofitting scheme highly depends on the bond performance of concrete-epoxy interface. During service life, structures are exposed to complicated and unavoidable mechanical and environmental situations that can cause bond deterioration. In order to ensure the structural safety in a long run, a comprehensive experiment focusing on the coupled effect of sustained load and moisture on the bond property of concrete-epoxy interface is conducted. A drastic deterioration of concrete-epoxy interfacial fracture toughness, up to 77%, is observed under coupled sustained load and moisture exposure. Based on our experimental investigation, a predictive model is developed to describe the bond property variations of concrete-epoxy interface against long-term sustained load and moisture. The proposed predictive model can be used to obtain a more reliable and accurate service life prediction and maintenance planning for FRP-bonded concrete structures.
Related Topics
Physical Sciences and Engineering Engineering Industrial and Manufacturing Engineering
Authors
, , ,