Article ID Journal Published Year Pages File Type
5437041 Cement and Concrete Research 2017 12 Pages PDF
Abstract
Stray current induced corrosion is a major technical challenge for modern electric railway systems. The leakage of stray current to surrounding reinforced concrete structures can lead to steel reinforcement corrosion and the subsequent disintegration of concrete. Steel fibre reinforced concrete has been increasingly used as the railway tunnel lining material but it is not clear if discrete steel fibres can still pick up and transfer stray current in the same way as conventional steel reinforcement and lead to similar corrosion reactions. The corrosion behaviour of steel fibres was investigated through voltammetry tests and electrochemical impedance spectroscopy. The presence of high concentration chloride ions was found to increase the pitting corrosion tendency of steel fibres in simulated concrete pore solutions and mortar specimens. The chloride threshold level for corrosion of steel fibres in concrete is approximately 4% NaCl (by mass of cement) which is significantly higher than that of conventional steel reinforcement.
Related Topics
Physical Sciences and Engineering Engineering Industrial and Manufacturing Engineering
Authors
,