Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
5444072 | Cryogenics | 2017 | 5 Pages |
Abstract
Mechanically pressing the ends of a copper braid in solid copper is an effective way of constructing solderless conductive straps for cryogenic applications. In this paper we present thermal conductance data of such a copper strap measured using the two-heater one-thermometer method. The measurements span a wide temperature range of 0.13-10Â K applicable to a variety of cryogenic systems employing liquid helium, pulse tube coolers, adiabatic demagnetization refrigerators, and others. Above â1.5Â K, the braid thermal conductivity dominates the strap conductance resulting in a near-linear dependence with temperature. The variation with temperature below â1.5Â K is near-quadratic indicating dominance of the pressed contact conductance at the strap ends. Electron-beam welding the braid to the strap ends is shown to be a promising solution for improving sub-Kelvin thermal conductance of the strap.
Related Topics
Physical Sciences and Engineering
Materials Science
Electronic, Optical and Magnetic Materials
Authors
R.C. Dhuley, M. Ruschman, J.T. Link, J. Eyre,