Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
5444543 | Energy Procedia | 2017 | 7 Pages |
Abstract
The fill factor determined from a measured current-voltage characteristic of a bare solar cell depends on the number and positions of the electrical contacting probes. Nine different geometries for contacting the front side busbars are used to measure the current-voltage (I-V) characteristics of a 5 busbar industrial-type passivated emitter and rear totally diffused (PERT) solar cell under standard testing conditions. The fill factors of the measured I-V characteristics vary from 78.5 %abs to 80.6 %abs. We further measure the contacting resistance of 3 different contacting probes to estimate the sensitivity of measurements with different contacting geometries on random resistance variations. The contacting resistance is 60 mΩ for nine-point probes and 80 mΩ for four- and single-point probes. We determine the magnitude of contacting resistance variations from measurements at different probe positions to be ±30 mΩ. Using this variation, we perform numerical simulations and find a larger sensitivity on random resistance variations for tandem- (pairs of current- and sense probes) compared to triplet (one sense- between two current probes) configurations. The corresponding fill factor deviation is approximately 0.1%abs for tandem configurations when the contacting resistances of up to two current probes are altered. The sensitivity for triplet configurations is negligible.
Related Topics
Physical Sciences and Engineering
Energy
Energy (General)
Authors
Christian N. Kruse, Martin Wolf, Carsten Schinke, David Hinken, Rolf Brendel, Karsten Bothe,