Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
5445378 | Energy Procedia | 2017 | 11 Pages |
Abstract
The present research investigates the effect of orientation and façades openness and glazing type on global energy consumption in typical offices under the specific climate of present areas in the south of Algeria using Eneryplus software version (8.4.0), a serie of simulations has been performed in order to establish the optimal window configuration in terms of area orientation and glazing type.
Related Topics
Physical Sciences and Engineering
Energy
Energy (General)
Authors
Zekraoui Djamel, Zemmouri Noureddine,