Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
5446333 | Energy Procedia | 2016 | 5 Pages |
Abstract
In this study, the cascade utilization of the flue gas waste heat in CHP-HBP was performed. In the proposed system, flue gas of the coal-fired boiler and exhaust steam of the turbine were recovered synthetically. The maximum heat-supply capacity and the thermodynamic performance of the full heating period was analyzed. The results showed that: in the novel system, the maximum heat-supply capacity is 22.51 MW higher than that of reference system, and the coal consumption rate is reduced by 10.91g/kWh. Meanwhile, during the whole heating period, the gross electric power is 7.37 million kWh higher than the reference system.
Keywords
Related Topics
Physical Sciences and Engineering
Energy
Energy (General)
Authors
Shifei Zhao, Xiaoze Du, Zhihua Ge, Yongping Yang,