Article ID Journal Published Year Pages File Type
5446703 Energy Procedia 2016 10 Pages PDF
Abstract
The results indicate that corrosion propagation after carbonation has reached the reinforcement, is three to six years depending on the ratio of concrete cover depth against the reinforcement diameter. While applying ETICS, corrosion accelerates for a short period of time up to one year. Temperature inside the wall rises above +10 °C throughout the year, meaning no more freeze-thaw damage. Corrosion of reinforcement in carbonated concrete after applying ETICS is so slow, that no cracking will develop. Drying out moisture or vapour diffusion from indoor air is not able to propagate corrosion of reinforcement in carbonated concrete.
Related Topics
Physical Sciences and Engineering Energy Energy (General)
Authors
, , , ,