Article ID Journal Published Year Pages File Type
5451034 Solar Energy 2016 13 Pages PDF
Abstract
This paper discusses the cited design criteria and presents an analysis aimed at identifying the potential storage solutions to be implemented into a Concentrated Solar Power (CSP) plant for electricity generation operating at temperatures between (170 °C) and (300 °C). The system so developed will be integrated in the 1 MWe CSP-ORC facility based on Fresnel technology that is currently under construction at Iresen's premises in Benguerir, Morocco. Detailed transient models of performance of two-tank and thermocline storage systems are presented. The annual simulations carried out reveal that thermocline solutions are globally more attractive, since they exhibit similar thermal performance but at a much lower (30% lower) cost.
Related Topics
Physical Sciences and Engineering Energy Renewable Energy, Sustainability and the Environment