Article ID Journal Published Year Pages File Type
5452766 Procedia Structural Integrity 2017 9 Pages PDF
Abstract
This paper shows the results obtained by fractographic (optical and electronic microscopy), metallographic, chemical analysis and numerical simulation: the root cause of the cracks was a phenomenon of pitting corrosion mainly located on the door back hinge and due to a local loss of coating. This made possible a fatigue fracture mechanism under normal operative cyclic loads.
Related Topics
Physical Sciences and Engineering Materials Science Materials Chemistry
Authors
, , , ,