Article ID Journal Published Year Pages File Type
5455547 Materials Science and Engineering: A 2017 7 Pages PDF
Abstract
Cold formability of friction stir processed aluminum composites was evaluated by bend-ductility test. Composites containing carbon nanotubes fractured during bending while those containing boron carbide particles survived; hybrid composites showed cracking but less than those containing solely nanotubes. Weak interfacial nanotube/aluminum bonding and inadequate nanotube distribution were found to be the possible reasons.
Related Topics
Physical Sciences and Engineering Materials Science Materials Science (General)