Article ID Journal Published Year Pages File Type
5467121 Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 2017 6 Pages PDF
Abstract
We report on the experimental results of the ionization efficiency of Rb and Cs using a surface ionization source prototype at Rare Isotope Science Project (RISP) of Institute for Basic Science (IBS). A hot-cavity surface ionization source has been studied in an off-line test bench equipped with a mass separator and a beam diagnostic system which allow accurate ionization efficiency measurements. Ionization efficiencies of 76% and 77% have been measured for Rb and Cs, respectively, from the Ta prototype of the RISP surface ionization source.
Related Topics
Physical Sciences and Engineering Materials Science Surfaces, Coatings and Films
Authors
, , , , , , , , , , , , ,