Abstract
The cell leak rate is extremely small, less than 0.01 cfm, given the very large cell size. The oxygen concentration method is accurate to approximately ±0.002 cfm. The pressure-temperature method is accurate to about ±1 cfm. The pressure-temperature leak rate method can be used as a confirmation of the oxygen method results or as a backup if the oxygen monitors are not working.