Article ID Journal Published Year Pages File Type
5475059 Annals of Nuclear Energy 2017 9 Pages PDF
Abstract
The simulation results showed that the CND failure probability increased by 23% after the power uprate. The sequence CDF increased by 16% after the power uprate. The results of the importance analyses indicated that the time to execute CND was not a significant factor in determining the success of CND. The uncertainty involved in the simulations of reactor coolant system thermal hydraulic responses is important in the determination of human error probability.
Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , ,