Article ID Journal Published Year Pages File Type
5475327 Annals of Nuclear Energy 2017 12 Pages PDF
Abstract
Having the capability to use filtered containment venting during a severe nuclear accident can significantly reduce its overall consequences. This study employs the MAAP-CANDU severe accident analysis code and the ADDAM atmospheric dispersion code to study the progression of: an unmitigated station blackout accident at a generic pressurized heavy water reactor, the release of radioactive material into the environment, the subsequent dispersion of the fission products through the atmosphere and the subsequent consequences (evacuation radius). The goal is to evaluate the application of filtered venting as an accident mitigation technology. Several aspects of filtered containment venting system design, like flow capacity, initiation protocols, filter efficiency, mass loading, and thermal loading are considered. An efficient and robust filtered containment venting system can reduce the amount of radiological materials emitted during an accident by 25 times or more, and as a result considerably reduce the off-site consequences of an accident.
Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , , , ,