In this paper the Authors analyze, compare and discuss the numerical indicators currently used to evaluate the lighting and the energy performance of new-designed and existing road lighting systems. To support the discussion, the use of the case study of road lighting of the historic town center of Pisa is proposed. For the case study the Authors have chosen a significant sample of 20 roads representative of 80 similar roads located in the historic town center. For the sample, geometric surveys, luminance and illuminance measurements, calculation of the national and international energy performance indicators have been carry out. The considerations made by the Authors, obtained with an investigation procedure of general validity, are useful to point out strengths and weaknesses of each indicator and to provide suggestions on the use of the appropriate indicators during the design stage of road lighting systems.