Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
5475576 | Energy | 2017 | 14 Pages |
Abstract
Simulations of processes of loading and unloading of compressed air storage were performed and then places where exergy destruction occurs were identified. The biggest exergy destruction occurs in the compressors (276.191Â MWh/cycle in total) and turbines (190.394Â MWh/cycle in total). Major destruction of exergy was also reported at control valve V2 (103.688Â MWh/cycle). Round trip efficiency of the system is 50%.
Related Topics
Physical Sciences and Engineering
Energy
Energy (General)
Authors
Lukasz Szablowski, Piotr Krawczyk, Krzysztof Badyda, Sotirios Karellas, Emmanuel Kakaras, Wojciech Bujalski,