Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
5477645 | Journal of Environmental Radioactivity | 2017 | 6 Pages |
Abstract
For planned and ongoing storage of liquid radioactive waste in a designated plant for a nuclear medicine therapy ward (decontamination system/decay system), detailed knowledge of basic parameters such as the amount of radioactivity and the necessary decay time in the plant is required. The design of the plant at the Department of Nuclear Medicine of the University of Cologne, built in 2001, was based on assumptions about the individual discharge of activity from patients, which we can now retrospectively validate. The decontamination factor of the plant is at present in the order of 10â9 for 131I. The annual discharges have been continuously reduced over the period of operation and are now in the region of a few kilobecquerels. This work emphasizes the high efficacy of the decontamination plant to reduce the amount of radioactivity released from the nuclear medicine ward into the environment to almost negligible levels.
Related Topics
Physical Sciences and Engineering
Energy
Nuclear Energy and Engineering
Authors
F. Sudbrock, K. Schomäcker, A. Drzezga,