Abstract
Continuous wave mud pulse telemetry system with a transmission rate of more than 12Â bps, is an irreplaceable high-speed data transmission technology for Measurement While Drilling (MWD) and Logging While Drilling (LWD) instruments used in modern oil drilling services. However, the valid signal is difficult to be obtained because of the disturbing of pump noise in the data transmission. Here, a differential signal extraction method for continuous wave mud pulse generator is applied to extract the effective mud pulse signal from pump noise. It utilizes dual sensor and a differential algorithm to extract the signal. To verify this method, the robustness was analyzed in the numerical simulation. In the actual test, a continuous wave mud pulse generator was designed, and a hydraulic circulation laboratory was built. The Signal to Noise Ratio (SNR) was risen from â13Â dB up to 25Â dB. The experimental results demonstrated the effectiveness of the designed mud pulse generator, and proved that this method can be a feasible way to solve the problem of signal extraction from pump noise.
Related Topics
Physical Sciences and Engineering
Earth and Planetary Sciences
Economic Geology
Authors
Jing Shao, Zhidan Yan, Suli Han, Hui Li, Tingzheng Gao, Xiufeng Hu, Chunming Wei,