Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
5493120 | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | 2017 | 4 Pages |
Abstract
Magnetic field errors and misalignments of magnetic and diagnostic components induce spurious emittance growth. The aim of this study is to correct the impact of such errors on the ELI-NP Gamma Beam System low energy line for an effective commissioning of the machine. To perform this study we use the simulation code elegant, for alignment and trajectory stabilization methods such as one-to-one steering, fast-trajectory-feedback (FTF) or global method and Dispersion Free Steering (DFS). We show the latter to be the most robust trajectory control method for magnetic elements and monitor errors.
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Instrumentation
Authors
G. Campogiani, S. Guiducci, A. Giribono, C. Vaccarezza, A. Variola,