Article ID Journal Published Year Pages File Type
5498970 Radiation Measurements 2016 28 Pages PDF
Abstract
This paper contains the results of studies into the possibilities and limitations of the use of UD-807 Panasonic dosimeters in extremity dosimetry. Detection efficiency, critical levels, detection limits, energy and angular dependence were determined with respect to the beta radiation emitted by 90Sr|90Y and photon radiation in the range of 33 keV-662 keV. The calibration coefficients, expressed in units of personal dose equivalent Hp(0.07), differed by no more than 10% for all types of radiation when the radiation reached the dosimeters at an angle of 0°. In other configurations, if the angle between the normal to the dosimeter surface and the radiation direction increased, the detection efficiency rapidly decreased - to a lesser extent in relation to the 33 keV photon radiation than to the beta radiation. The reduction was insignificant for photon radiation emitted by 137Cs.
Related Topics
Physical Sciences and Engineering Physics and Astronomy Radiation
Authors
,