In patients with single-ventricle physiology, DTI and pulmonary vein Doppler echocardiographic parameters correlated modestly with direct measurement of VEDP and may be helpful in identifying patients with elevated filling pressures. In addition, single left ventricles had better systolic and diastolic performance than single right ventricles. DTI systolic velocities and left ventricular MPI correlated well with ventricular ejection fraction.