Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
5650635 | The American Journal of Emergency Medicine | 2017 | 28 Pages |
Abstract
During central venous catheterization through the right internal jugular vein, inserting guidewires to depths of 15 or 17.5Â cm before tissue dilation reduced the incidence of arrhythmic episodes compared to a depth of 20Â cm.
Keywords
Related Topics
Health Sciences
Medicine and Dentistry
Emergency Medicine
Authors
Jung-Man Lee, Jiwon Lee, Jin-Young Hwang, Jee-Eun Chang, Heyrim Kim, Sohee Oh, Eun-Ah Oh, Seong-Won Min,