Abstract
The present study addresses the question of evaluating, by combining both experimental and numerical approaches, the stress/strain distribution within a complete model of the entire lower bony chain. With this purpose an experimental model and a complete 3D finite element one were realised. A load of 700Â N has been applied at the top of pelvis and the feet were rigidly fixed. Obtained results reveal interesting consequences deriving by taking into account the complete bony chain; it is possible to get information on load sharing between bones, location of high strain concentrations, and bone relative motion.
Related Topics
Health Sciences
Medicine and Dentistry
Emergency Medicine
Authors
V. Filardi, D. Milardi,