Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
5709163 | The Journal of Arthroplasty | 2017 | 5 Pages |
Abstract
Prophylactic cerclage wire placement increases the rotation and energy to failure in well-fixed press-fit femoral implants. The increase in torsional energy needed for failure may reduce the risk of early periprosthetic fracture. Further studies are needed to evaluate cost vs benefit and long-term outcomes of prophylactic wiring. Based on the results of our study, consideration of prophylactic wiring should be addressed on a case-to-case basis.
Related Topics
Health Sciences
Medicine and Dentistry
Orthopedics, Sports Medicine and Rehabilitation
Authors
Andrew C. MD, John R. MS, Jennifer S. PhD, Shane R. DO, Gregory J. MD, William A. MD,