ObjectiveThe aim of this study was to determine whether a portal flow of <1,000 mL/min in orthotopic liver transplantation (OLT) is associated with a higher incidence of early graft dysfunction (EGD) and graft loss.MethodsA retrospective study was performed of 540 OLTs carried out consecutively from December 2004 to December 2013. Patients were divided into 2 groups: group A, portal flow <1,000 mL/min; and group B, portal flow >1,000 mL/min. We studied the incidence of EGD and graft survival. A subanalysis was performed to define the minimum acceptable portal flow/100 g of liver weight to reduce the development EGD and graft loss.ResultsGroup A included 29 patients and group B, 511 patients. Group A had significantly lower-weight donors and recipients, female recipients with cholestatic disease, lower MELD scores, and lower hepatic artery flow. EGD occurred in 7 patients in group A (24.1%) versus 101 patients in group B (19.8%; P = .43). No significant differences were found in 1- and 5-year graft survival. A portal flow of <80 mL/min/100 g of liver weight was related to a significantly higher risk of developing EGD (odds ratio, 4.35; 95% confidence interval [CI], 1.46-12.91; P = .008) and graft loss (hazard ratio, 4.05; 95% CI, 1.32-12.42; P = .014).ConclusionsIntraoperative portal flow of <1,000 mL/min in OLT was not related per se with a higher incidence of EGD or graft loss. Significantly higher risk of developing EGD and graft loss was associated with a portal flow of <80 mL/min/100 g of liver weight.