IntroductionFar-Forward Damage Control Laparotomies (DCLs) might provide direct-compression of visceral hemorrhage, however, suturing is a limiting factor, especially for non-physicians. We thus compared abbreviated skin closures comparing skin-suture (SS) versus wound-clamp (WC), on-board a research aircraft in weightlessness (0g) and normal gravity (1g).MethodsSurgeons conducted DCLs on a surgical-simulator; onboard the hangered-aircraft (1g), or during parabolic flight (0g), randomized to either WC or SS.ResultsTen surgeons participated. Two (40%) surgeons randomized to suture in 0g were incapacitated with motion-sickness, and none were able to close in either 1 or 0g. With WC, two completely closed in 1g as did three in 0g, despite having longer incisions (p = 0.016). Overall skin-closure with WC was significantly greater in both 1g (p = 0.016) and 0g (p = 0.008).ConclusionsWC was more effective in 1g and particularly 0g. Future studies should address the utility of abbreviated WC abdominal closure to facilitate potential Far-Forward DCL.Trial registrationID ISRCTN/77929274.